Place of Origin Germany
Brand Name SIEMENS
Certification CE
Model Number 6ES7516-3AN02-0AB0
Document Product Brochure PDF
Product Details
Number Of Digital Inputs:
32
Operating Temperature:
-20°C To +60°C
Special Features:
Integrated Web Server, Safety Integrated, High-Speed Counting Functions
Communication Interfaces:
PROFINET, PROFIBUS, Ethernet/IP, Modbus TCP, OPC UA
Memory:
2 MB
Number Of Digital Outputs:
32
Number Of Analog Inputs:
8
Protection Rating:
IP20
Cpu Type:
S7-1516F
Programming Languages:
Ladder Logic, Function Block Diagram, Structured Control Language
Number Of Analog Outputs:
8
Power Supply:
24 VDC
Weight:
0.5 Kg
Dimensions:
130 X 125 X 130 Mm
Certifications:
CE, UL, CSA
Payment & Shipping Terms
Minimum Order Quantity
1
Price
USD
Packaging Details
15,10 x 15,40 x 4,60
Delivery Time
10-12Days
Payment Terms
L/C, T/T
Supply Ability
100
Product Description

SIEMENS 6ES7516-3AP03-0AB0 PROFINET IRT WITH 2-PORT SWITCH, 2ND INTERFACE: PROFINET RT, 3RD INTERFACE: PROFIBUS

The SIEMENS 6ES7516-3AP03-0AB0 is a central processing unit (CPU) that is part of the SIMATIC S7-1500 automation system. Here are the key details about this CPU:

PROFINET IRT with 2-Port Switch:
- The CPU has two PROFINET ports with an integrated 2-port switch.
- This allows the CPU to be directly connected to a PROFINET network in a line topology without requiring additional switches.
- The PROFINET interface supports the IRT (Isochronous Real-Time) protocol for highly deterministic and synchronized communication.

Second PROFINET Interface (PROFINET RT):
- In addition to the PROFINET IRT interface, the CPU also has a second PROFINET RT (Real-Time) interface.
- This provides additional network connectivity options and flexibility for the automation system.

PROFIBUS Interface:
- This CPU model is equipped with a third interface - a PROFIBUS interface.
- PROFIBUS is an industrial fieldbus protocol commonly used for connecting automation devices.
- The PROFIBUS interface allows the CPU to communicate with other PROFIBUS-enabled devices on the network.

Other Features:
- Work Memory: 1 MB for program and 5 MB for data
- Powerful CPU with high processing capabilities
- SIMATIC memory card required for operation
- Part of the modular SIMATIC S7-1500 system
- Programmed using the STEP 7 engineering software

The key distinguishing feature of this CPU model is the inclusion of the third PROFIBUS interface, in addition to the dual PROFINET interfaces. This provides extensive connectivity options and makes the CPU well-suited for applications that require integration with both PROFINET and PROFIBUS networks.

General information
Product type designation CPU 1516-3 PN/DP
HW functional status FS04
Firmware version V3.1
● FW update possible Yes
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode Yes; Distributed and central; with minimum OB 6x cycle of 375 µs (distributed) and 1 ms (central)
● SysLog Yes
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V19 (FW V3.1) / V18 (FW V3.0) or higher; with older TIA Portal versions configurable as 6ES7516-3AN02-0AB0
Configuration control
via dataset Yes
Display
Screen diagonal [cm] 6.1 cm
Control elements
Number of keys 8
Mode buttons 2
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
● Mains/voltage failure stored energy time 5 ms
Input current
Current consumption (rated value) 0.69 A
Current consumption, max. 1.08 A
Inrush current, max. 1.15 A; Rated value
I²t 0.6 A²·s
Power
Infeed power to the backplane bus 12 W
Power consumption from the backplane bus (balanced) 6.7 W
Power loss
Power loss, typ. 4 W
Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory
● integrated (for program) 2 Mbyte
● integrated (for data) 7.5 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup
● maintenance-free Yes
CPU processing times
for bit operations, typ. 6 ns
for word operations, typ. 7 ns
for fixed point arithmetic, typ. 9 ns
for floating point arithmetic, typ. 37 ns
CPU-blocks
Number of elements (total) 8 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
● Size, max. 7.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range 0 ... 65 535
● Size, max. 1 Mbyte
FC
● Number range 0 ... 65 535
● Size, max. 1 Mbyte
OB
● Size, max. 1 Mbyte
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 250 µs
● Number of process alarm OBs 50
● Number of DPV1 alarm OBs 3
● Number of isochronous mode OBs 3
● Number of technology synchronous alarm OBs 2
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2

 

 