logo
Shenzhen Voboal Industrial Automation Co., Ltd.
Email sale@voboal.com TEL: 86-0755-32825139
Home > products > SIEMENS SIMATIC PLC >
SIEMENS 6ES7510-1DJ01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND
  • SIEMENS 6ES7510-1DJ01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND

SIEMENS 6ES7510-1DJ01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND

Place of Origin Germany
Brand Name SIEMENS
Certification CE
Model Number 6ES7510-1DJ01-0AB0
Document Product Brochure PDF
Product Details
Payment & Shipping Terms
Minimum Order Quantity
1
Price
USD
Packaging Details
15,10 x 15,40 x 4,60
Delivery Time
10-12Days
Payment Terms
L/C, T/T
Supply Ability
100
Product Description

SIEMENS 6ES7510-1DJ01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND

The SIEMENS 6ES7510-1DJ01-0AB0 is a central processing unit (CPU) that is part of the SIMATIC S7-1500 automation system. Here are the key details about this CPU:

SIMATIC Memory Card Required:
- Like other SIMATIC S7-1500 CPUs, this model requires a SIMATIC memory card to be inserted for operation.
- The memory card provides storage for the user program, configuration data, and other runtime information.

Busadapter Required for Port 1 and Port 2:
- This CPU has two Ethernet/PROFINET ports.
- However, to use these ports, a separate busadapter is required to be connected.
- The busadapter provides the necessary connectivity for the Ethernet/PROFINET interfaces.

Other Features:
- CPU Type: CPU 1510SP-1 PN
- Work Memory: 150 KB for program and 1 MB for data
- Compact, space-saving design in an ET 200SP module
- Part of the modular SIMATIC S7-1500 system
- Programmed using the STEP 7 engineering software

The key distinguishing features of this CPU model are its compact, space-saving design in the ET 200SP module format and the requirement for a busadapter to be connected to the Ethernet/PROFINET ports.

This makes the CPU 1510SP-1 PN well-suited for applications where space is limited, such as in distributed control systems or in confined areas. The busadapter requirement provides flexibility in terms of the type of network connectivity required for the application.

Overall, this CPU model is a compact and versatile option within the SIMATIC S7-1500 automation system, designed for applications that need a smaller form factor but still require the capabilities of the S7-1500 platform.

 

General information
Product type designation CPU 1510SP-1 PN
HW functional status FS05
Firmware version V2.9
Product function
● I&M data Yes; I&M0 to I&M3
● Module swapping during operation (hot swapping) Yes; Multi-hot swapping
● Isochronous mode Yes; Only with PROFINET; with minimum OB 6x cycle of 625 µs
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V17 (FW V2.9) / V13 SP1 Update 4 (FW V1.8) or higher
Configuration control
via dataset Yes
Control elements
Mode selector switch 1
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
● Mains/voltage failure stored energy time 5 ms
Input current
Current consumption (rated value) 0.6 A
Current consumption, max. 0.9 A
Inrush current, max. 4.7 A; Rated value
I²t 0.14 A²·s
Power
Infeed power to the backplane bus 8.75 W
Power loss
Power loss, typ. 5.6 W
Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory
● integrated (for program) 100 kbyte
● integrated (for data) 750 kbyte
Load memory
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup
● maintenance-free Yes
CPU processing times
for bit operations, typ. 72 ns
for word operations, typ. 86 ns
for fixed point arithmetic, typ. 115 ns
for floating point arithmetic, typ. 461 ns
CPU-blocks
Number of elements (total) 4 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
● Size, max. 750 kbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range 0 ... 65 535
● Size, max. 100 kbyte
FC
● Number range 0 ... 65 535
● Size, max. 100 kbyte
OB
● Size, max. 100 kbyte
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 500 µs
● Number of process alarm OBs 50
● Number of DPV1 alarm OBs 3
● Number of isochronous mode OBs 1
● Number of technology synchronous alarm OBs 2
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2
● Number of diagnostic alarm OBs 1
Nesting depth
● per priority class 24
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— adjustable Yes
IEC counter
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
S7 times
● Number 2 048
Retentivity
— adjustable Yes
IEC timer
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 128 kbyte; Available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB
Flag
● Size, max. 16 kbyte
● Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustable Yes
● Retentivity preset No
Local data
● per priority class, max. 64 kbyte; max. 16 KB per block
Address area
Number of IO modules 1 024; max. number of modules / submodules
I/O address area
● Inputs 32 kbyte; All inputs are in the process image
● Outputs 32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
per CM/CP
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
Subprocess images
● Number of subprocess images, max. 32
Address space per module
● Address space per module, max. 288 byte; For input and output data respectively
Address space per station
● Address space per station, max. 2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules
Hardware configuration
Number of distributed IO systems 32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
● Via CM 1
Number of IO Controllers
● integrated 1
● Via CM 0
Rack
● Modules per rack, max. 80; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules
● Quantity of operable ET 200SP modules, max. 64
● Quantity of operable ET 200AL modules, max. 16
PtP CM
● Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots

 

SIEMENS 6ES7510-1DJ01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 0

Contact Us at Any Time

+8613760462017
Sienteng Zhongbao Industrial Park, Longdong Community, Baolong Street, Longgang District, Shenzhen
Send your inquiry directly to us