Place of Origin | Germany |
Brand Name | SIEMENS |
Certification | CE |
Model Number | 6ES7517-3UP00-0AB0 |
Document | Product Brochure PDF |
SIEMENS 6ES7517-3UP00-0AB0 PROFIBUS, 2 NS BIT PERFORMANCE, SIMATIC MEMORY CARD REQUIRED
Understood. Here are the key details about the SIEMENS 6ES7517-3UP00-0AB0 PROFIBUS controller module:
Product Description:
- The 6ES7517-3UP00-0AB0 is a SIMATIC S7-1500 CPU module with PROFIBUS connectivity.
- Like the 6ES7517-3FP00-0AB0, it features a PROFIBUS interface with 2ns bit performance for high-speed data exchange.
- This module also requires a SIMATIC memory card for program storage and additional functionality.
Key Features:
- PROFIBUS interface with 2ns bit performance for deterministic real-time communication.
- Suitable for time-critical applications such as motion control and manufacturing processes.
- Integrated PROFIBUS master functionality.
- Requires a SIMATIC memory card for program storage and additional features.
- Powerful CPU with 2 MB work memory and 10 MB load memory.
Connectivity:
- 1 x PROFIBUS interface for connecting PROFIBUS devices and networks.
Performance:
- 2ns bit performance for high-speed, deterministic PROFIBUS communication.
- Enables precise control and synchronization of connected devices.
SIMATIC Memory Card:
- The 6ES7517-3UP00-0AB0 module requires a SIMATIC memory card for program storage and additional functionality.
- The memory card provides the necessary storage capacity and enables features like firmware updates, backup, and restore functionality.
Certifications:
- According to the information available, the 6ES7517-3UP00-0AB0 module likely has relevant industrial certifications and approvals, such as:
- IEC 61131-2 (Programmable controllers)
- UL Recognized Component marking
- Hazardous Locations approvals (e.g., Class I, Division 2)
- Marine classification society approvals
In summary, the SIEMENS 6ES7517-3UP00-0AB0 is a PROFIBUS controller module with 2ns bit performance, designed for high-speed, deterministic communication in SIMATIC S7-1500 automation systems. It requires a SIMATIC memory card for program storage and additional functionality, similar to the 6ES7517-3FP00-0AB0.
General information | ||
Product type designation | CPU 1517TF-3 PN/DP | |
HW functional status | FS11 | |
Firmware version | V3.1 | |
● FW update possible | Yes | |
Product function | ||
● I&M data | Yes; I&M0 to I&M3 | |
● Isochronous mode | Yes; Distributed and central; with minimum OB 6x cycle of 250 µs (distributed) and 1 ms (central) | |
● SysLog | Yes | |
Engineering with | ||
● STEP 7 TIA Portal configurable/integrated from version | V19 (FW V3.1) / V14 (FW V2.0) or higher | |
Configuration control | ||
via dataset | Yes | |
Display | ||
Screen diagonal [cm] | 6.1 cm | |
Control elements | ||
Number of keys | 6 | |
Mode selector switch | 1 | |
Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
Reverse polarity protection | Yes | |
Mains buffering | ||
● Mains/voltage failure stored energy time | 5 ms | |
Input current | ||
Current consumption (rated value) | 1.55 A | |
Current consumption, max. | 1.9 A | |
Inrush current, max. | 1.9 A; Rated value | |
I²t | 0.4 A²·s | |
Power | ||
Infeed power to the backplane bus | 12 W | |
Power consumption from the backplane bus (balanced) | 30 W | |
Power loss | ||
Power loss, typ. | 24 W | |
Memory | ||
Number of slots for SIMATIC memory card | 1 | |
SIMATIC memory card required | Yes | |
Work memory | ||
● integrated (for program) | 3 Mbyte | |
● integrated (for data) | 8 Mbyte | |
Load memory | ||
● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte | |
Backup | ||
● maintenance-free | Yes | |
CPU processing times | ||
for bit operations, typ. | 2 ns | |
for word operations, typ. | 3 ns | |
for fixed point arithmetic, typ. | 3 ns | |
for floating point arithmetic, typ. | 12 ns | |
CPU-blocks | ||
Number of elements (total) | 12 000; Blocks (OB, FB, FC, DB) and UDTs | |
DB | ||
● Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 | |
● Size, max. | 8 Mbyte; For DBs with absolute addressing, the max. size is 64 KB | |
FB | ||
● Number range | 0 ... 65 535 | |
● Size, max. | 1 Mbyte | |
FC | ||
● Number range | 0 ... 65 535 | |
● Size, max. | 1 Mbyte | |
OB | ||
● Size, max. | 1 Mbyte | |
● Number of free cycle OBs | 100 | |
● Number of time alarm OBs | 20 | |
● Number of delay alarm OBs | 20 | |
● Number of cyclic interrupt OBs | 20; with minimum OB 3x cycle of 100 µs | |
● Number of process alarm OBs | 50 | |
● Number of DPV1 alarm OBs | 3 | |
● Number of isochronous mode OBs | 3 | |
● Number of technology synchronous alarm OBs | 2 | |
● Number of startup OBs | 100 | |
● Number of asynchronous error OBs | 4 | |
● Number of synchronous error OBs | 2 | |
● Number of diagnostic alarm OBs | 1 | |
Nesting depth | ||
● per priority class | 24; Up to 8 possible for F-blocks |